Call 08048600246 70% Response Rate

our range

Analytical Instruments

Offering you a complete choice of products which include soxroc extraction unit, lab equipments analyzer, analyzer unit instruments, stack dust monitor, air quality monitor and ambient air monitoring instrument.
  • SOXROC Extraction Unit
  • SOXROC Extraction Unit
  • SOXROC Extraction Unit
SOXROC Extraction Unit

SOXROC Extraction Unit

Price on Request

Product Brochure

Voltage110 V
Frequency50 Hz
ApplicationIndustrial Use, Laboratory Use
ModelSOXROC Extraction Unit
Country of OriginMade in India
SOXROC EXTRACTION UNITThe OPSIS LiquidLINE SoxROC Extraction Unit is an automated Soxhlet instrument that can extract fat according to official methods. The instrument is based on Randall and Twisselmann techniques, using hot solvent and a closed system to reduce extraction time versus manual Soxhlet. The SoxROC follows officially approved methods for fat extraction. The SoxROC is designed to be flexible and is therefore also capable of extractions using other solvents and samples. Available in 2 and 6 position models.
Features:
Reduce Time. Reduce ErrorsWith SoxROC, You Can Extract As Many As 42 Samples Per Day With No Loss In Precision Or Accuracy.Automation Of All Extraction Steps And An Innovative Batch Handling Reduces Risk For Errors. Typically Up To Five Times Faster Than The Classical Soxhlet Technique.
Reduce CostsUnique Sealing System With More Than 90% Recovery Reduces Cost For Solvents And Efficient Water Cooling Reduce Water Consumption.A Large Selection Of Seals, Cups And Standard Thimbles Reduces Costs When Changing Between Applications And Solvents.One Single Compact System Without Wires Or Computers Reduces Costs For Installation And Operation.
Add Flexibility. Add Safety.Unique Control Of Solvent Removal Adds Flexibility For Different Applications.Security With High Standard Against Dust, Liquids And Explosives. All Valves Close To Solvents Are ATEX Classified.Operator Safety Is Important And The SoxROC Is Equipped With Protection Shield, Closed Addition Of Solvents, And Easy Removal Of Recovered Solvents.

View Complete details

get quote request a call back
  • Lab Equipments Analyzer
  • Lab Equipments Analyzer
  • Lab Equipments Analyzer
  • Lab Equipments Analyzer
  • Lab Equipments Analyzer
Lab Equipments Analyzer

Lab Equipments Analyzer

Price on Request

Product Brochure

Machine TypeAnalyzer Equipments
Model Name/NumberKjelROC Analyzer Unit
Usage/ApplicationLaboratory Use
ColorMulti
BrandKjelROC

The OPSIS LiquidLINE KjelROC range of analyzers offers innovative, precise and cost efficient solutions for Distillation, Titration and determination of protein according to the Kjeldahl method. Unique Preditive Titration, patent pending, gives several advantages in the lab.

 

Features:

 

Increase Efficiency. Reduce Costs

The Possibility To Send And Receive Results Without Additional Software, Computers And Cables, Significantly Reduces The Integration And IT Costs.

Process Data Files Directly In The KjelROC Analyzer. This Reduces Costs When Integrating With Your LIMS Or Other Systems.

 

Improved Analytical Results

The OPSIS LiquidLINE Predictive Titration Lowers The Relative Standard Deviation (RSD) And Increases Flexibility With Different Indicators.

Large, Refillable Burette Saves Time And Costs When Moving Between High And Low Content Protein.

Performance Tracking Saves Time When Following The Instrument Performance Over Time.

The Unique Predicive Titration System Lowers The RSD.

The 50 Ml Burette With Automatic Refill Makes It Easy To Change Between High And Low Protein Analysis.

 

Low Maintenance Costs

Prepared For ISO 17025 And GLP Features, Reduce Time And Costs When Integrating The Instrument Into The Lab Procedures.

Component Lifetime And Maintenance Costs Are Optimized With The Help Of OPSIS Component Traceability Program. It Allows Easy Diagnostics And Follow-Up Of Both Instruments And Components.

Adaptive Workflow

The KjelROC Analyzer Is Fully Flexible To Adapt To Your Existing Lab Procedures Or You Can Use Our Ready To Use Programs. You Are Always In Control With Our Customizable Touch Screen, Where You Can Define Your Own Workflow.

View Complete details

get quote request a call back
  • Analyzer Unit Instruments
  • Analyzer Unit Instruments
  • Analyzer Unit Instruments
Analyzer Unit Instruments

Analyzer Unit Instruments

Price on Request

Product Brochure

Model Name/NumberOPSIS LiquidLINE KjelROC Digestors
Usage/ApplicationLaboratory Use
I Deal InNew Only
Programme1 Pre-heat program and 4 pre-defined programs
Heating20 degree C to 450 degree C
Country of OriginMade in India

The OPSIS LiquidLINE KjelROC range of analyzers offers innovative, precise and cost efficient solutions for Distillation, Titration and determination of protein according to the Kjeldahl method. Unique Preditive Titration, patent pending, gives several advantages in the lab.

 

Features:

 

Increase Efficiency. Reduce Costs

The Possibility To Send And Receive Results Without Additional Software, Computers And Cables, Significantly Reduces The Integration And IT Costs.

Process Data Files Directly In The KjelROC Analyzer. This Reduces Costs When Integrating With Your LIMS Or Other Systems.

 

Improved Analytical Results

The OPSIS LiquidLINE Predictive Titration Lowers The Relative Standard Deviation (RSD) And Increases Flexibility With Different Indicators.

Large, Refillable Burette Saves Time And Costs When Moving Between High And Low Content Protein.

Performance Tracking Saves Time When Following The Instrument Performance Over Time.

The Unique Predicive Titration System Lowers The RSD.

The 50 Ml Burette With Automatic Refill Makes It Easy To Change Between High And Low Protein Analysis.

 

Low Maintenance Costs

Prepared For ISO 17025 And GLP Features, Reduce Time And Costs When Integrating The Instrument Into The Lab Procedures.

Component Lifetime And Maintenance Costs Are Optimized With The Help Of OPSIS Component Traceability Program. It Allows Easy Diagnostics And Follow-Up Of Both Instruments And Components.

Adaptive Workflow

The KjelROC Analyzer Is Fully Flexible To Adapt To Your Existing Lab Procedures Or You Can Use Our Ready To Use Programs. You Are Always In Control With Our Customizable Touch Screen, Where You Can Define Your Own Workflow.

View Complete details

get quote request a call back
  • Stack Dust Monitor
  • Stack Dust Monitor
  • Stack Dust Monitor
Stack Dust Monitor

Stack Dust Monitor

Price on Request

Product Brochure

Usage/ApplicationDust Monitor
BrandDynoptic
Model Name/NumberDSL340
Accuracy+2 to -2 %
Voltage+24 VDC
Measuring Range0.0 - 1000.0 mg/m3
Warranty24 months
The DSL-340 uses the innovative Dynamic Detection Principle (DDP) which measures fluctuations in the intensity of a light beam, using a folded beam Transceiver/Reflector arrangement. Increased dust or particulate density in the stack causes the amplitude of these fluctuations to increase. When calibrated against standard reference measurements, the amplitude of this signal relates directly to the dust concentration in the stack and this can be presented as a reading in mg/m³.

View Complete details

get quote request a call back
Air Quality Monitor

Air Quality Monitor

Price on Request
We are offering the best quality of Mobile Air Quality Monitoring in which a continuous air quality monitoring station was installed on a van and configured to measure PM1, PM2.5, PM10, CO, SO2, NOX, RH, and temperature.

Specifications:
  • Brand: Aeroqual
  • Primary standard computer
  • Controlled mass flow calibrator
  • Datalogger/computer data acquisition system

View Complete details

get quote request a call back
Ambient Air Monitoring Instrument

Ambient Air Monitoring Instrument

Price on Request

We have carved a niche in the domain by manufacturing and supplying the best class array of Open Path Air Quality Monitoring - Laser Diode. Able to house 4 laser diode heads, it is precisely manufactured using the finest quality laser diode under the prudent observation of well-qualified professionals. Having laser control and data sampling system, it is widely applauded to be used for determining extent of air polluting content in atmosphere. This Open Path Air Quality Monitoring - Laser Diode can be availed from us in multitude of technical specifications at marginal prices within committed delivery time.

Key points:

  • Aids in measuring the presence of carbon monoxide, ammonia and other toxic gases in environment
  • Helpful in regulating emission of air pollutants
  • Simple installation
  • High performance and longer service life

Brand Opsis


Model AR500S


Application Environment

View Complete details

get quote request a call back

EXPLORE MORE CATEGORIES